Isolator Switches

Isolator Switches are designed to isolate an electrical circuit from its power source. Isolator switches does not have any interruption capacity. It does not have any making or breaking capacity.

Isolator switches are only intended to be operated on open circuit. That means, Isolator switches must be closed on open circuit and then other means of device (like C.B.) to energize line or isolaor switches must be opened after opening upstream device (like C.B.) to de-energize line.

Isolator switches are purely mechanical device and it can conduct normal operational currents as well as under short circuit current for defined period.

Isolator switches complies to IEC 60947-1 and IEC 60947-3.

Image 21
Load Switches, Isolator, Disconnector Switch And Circuit Breaker Difference 4

Load Switches (Load Break Switch)

Load switches are designed to isolate an electrical circuit from its power source under load condition. It can also be termed as on load disconnectors or load break switch (LBS). Load switches may have short circuit making capacity but it does not possess a short circuit breaking capacity.

Load break switches are devices used to open an electrical circuit by isolating the source from the consumer. Whether they are manual, motorised or with a trip function, these devices ensure the on-load making, breaking and safety disconnection of low-voltage electrical circuits. Easy to assemble and easy to use, they are suitable for structures evolving in the industrial sector, public distribution, as well as emergency switching, distribution panels and motor feeders.

Load Switches are intended to be operated while current is still passing through circuit. That means Load switches can be closed or open on existing energized line.

Load switches are purely mechanical device and it can conduct normal operational currents and short circuit current for a defined period. Load switches are capable of operational currents, making currents and breaking currents under normal operating conditions.

Load switches complies to IEC 60947-1 and IEC 60947-3.

Load Isolation Switch
Load Switches, Isolator, Disconnector Switch And Circuit Breaker Difference 5

Circuit Breakers

There are various circuit breakers available for various application.

 Circuit breaker can be Electro Mechanical (ACB, VCB etc) or Purely Mechanical (MCCB, MCB etc) device based on application. Circuit breakers can be used with or without Isolators, Load switches and switch disconnector.

 Circuit breakers are capable of carrying operation currents, making and breaking currents under normal operating conditions; also, making, carrying fault current and breaking currents for specified time under abnormal circuit condition (faulty or short circuit condition).

Image 23
Load Switches, Isolator, Disconnector Switch And Circuit Breaker Difference 6